{"id":251,"date":"2020-06-25T22:34:50","date_gmt":"2020-06-25T22:34:50","guid":{"rendered":"https:\/\/www.itadviser.mx\/blog\/?p=251"},"modified":"2026-04-30T14:52:08","modified_gmt":"2026-04-30T20:52:08","slug":"control-de-temperatura-en-centros-de-datos","status":"publish","type":"post","link":"https:\/\/www.itadviser.mx\/blog\/control-de-temperatura-en-centros-de-datos\/","title":{"rendered":"Lo que debes saber para tener un mejor control de temperatura en centros de datos"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"251\" class=\"elementor elementor-251\">\n\t\t\t\t<div class=\"elementor-element elementor-element-df8a5a8 e-flex e-con-boxed e-con e-parent\" data-id=\"df8a5a8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9403676 elementor-widget elementor-widget-image\" data-id=\"9403676\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"390\" src=\"https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2020\/06\/control-de-temperatura-en-centros-de-datos-1024x390.png\" class=\"attachment-large size-large wp-image-9657\" alt=\"control de temperatura en centros de datos\" srcset=\"https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2020\/06\/control-de-temperatura-en-centros-de-datos-1024x390.png 1024w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2020\/06\/control-de-temperatura-en-centros-de-datos-300x114.png 300w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2020\/06\/control-de-temperatura-en-centros-de-datos-768x292.png 768w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2020\/06\/control-de-temperatura-en-centros-de-datos-1536x584.png 1536w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2020\/06\/control-de-temperatura-en-centros-de-datos-2048x779.png 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-224643c e-con-full e-flex e-con e-parent\" data-id=\"224643c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c1ccfd7 elementor-widget elementor-widget-text-editor\" data-id=\"c1ccfd7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p style=\"font-style: normal; font-weight: var( --e-global-typography-primary-font-weight ); color: #000000; font-family: var( --e-global-typography-primary-font-family ), Sans-serif; text-align: right;\" data-elementor-setting-key=\"title\" data-pen-placeholder=\"Teclea aqu\u00ed...\"><span style=\"font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-size: 1rem; white-space-collapse: preserve;\">Zabdiel Olvera | Asesor comercial en Adviser<\/span><span style=\"font-family: var( --e-global-typography-primary-font-family ), Sans-serif; font-size: 2.375rem; font-weight: var( --e-global-typography-primary-font-weight );\">\u00a0<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-57b75bc e-con-full e-flex e-con e-parent\" data-id=\"57b75bc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-342080a elementor-widget elementor-widget-heading\" data-id=\"342080a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><br><span style=\"color: var(--ast-global-color-2);font-family: Alatsi, sans-serif;font-size: 2.375rem;font-weight: inherit;text-align: var(--text-align)\">Importancia de tener un buen control de temperatura en centros de datos<\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3612d6f e-con-full e-flex e-con e-parent\" data-id=\"3612d6f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-88436e1 elementor-widget elementor-widget-text-editor\" data-id=\"88436e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"color: rgb(0, 0, 0); font-family: &quot;Franklin Gothic Book&quot;, sans-serif; font-size: 12pt; font-style: inherit; font-weight: inherit;\">Los equipos electr\u00f3nicos dado su operatividad y su dise\u00f1o, trabajan en un cierto rango de temperatura el cual permite que opere de forma adecuada, sin embargo al salirse de ese par\u00e1metro, puede presentar problemas de operaci\u00f3n, muchos de ellos al tener una temperatura elevada, entran en modo de protecci\u00f3n y pueden llegar apagarse para evitar da\u00f1os f\u00edsicos de los componentes internos.<\/span><br><\/p>\n<p><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt;\">Esto puede presentar un problema para el trabajo continuo que se tiene en un centro de datos en una empresa, ya que se mantiene trabajando las 24 horas, los 365 d\u00edas del a\u00f1o.<\/span><\/p>\n<p><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt;\">El paro en la operaci\u00f3n significa p\u00e9rdida de tiempo y a su vez significa p\u00e9rdida de dinero.<\/span><\/p>\n<p><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt;\">Por lo anterior, para mantener un buen control de temperatura en centros de datos y evitar el paro de los equipos por ese par\u00e1metro, se utiliza un <a href=\"https:\/\/www.itadviser.mx\/blog\/elegir-un-aire-acondicionado-de-precision\/\"><b>sistema de aire acondicionado<\/b><\/a> para solventar ese problema.<\/span><\/p>\n<p><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt;\">Hoy en d\u00eda muchos Data Center ya implementan sistemas de aire acondicionado, sin embargo la mayor\u00eda de ellos no tienen un sistema adecuado. Tienen <a href=\"https:\/\/www.itadviser.mx\/blog\/4-fallas-comunes-en-los-sistemas-de-aire-acondicionado\/\"><b>problemas energ\u00e9ticos, problemas de enfriamiento, mantenimiento, operatividad, etc<\/b><\/a>.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0515c0c e-con-full e-flex e-con e-parent\" data-id=\"0515c0c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1bf63ca elementor-widget elementor-widget-image\" data-id=\"1bf63ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"920\" height=\"508\" src=\"https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2020\/06\/control-de-temperatura-en-centros-de-datos-it-adviser.png\" class=\"attachment-large size-large wp-image-9659\" alt=\"control de temperatura en centros de datos\" srcset=\"https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2020\/06\/control-de-temperatura-en-centros-de-datos-it-adviser.png 920w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2020\/06\/control-de-temperatura-en-centros-de-datos-it-adviser-300x166.png 300w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2020\/06\/control-de-temperatura-en-centros-de-datos-it-adviser-768x424.png 768w\" sizes=\"(max-width: 920px) 100vw, 920px\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5eda9f4 e-con-full e-flex e-con e-parent\" data-id=\"5eda9f4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-443b7f5 elementor-widget elementor-widget-text-editor\" data-id=\"443b7f5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"color: rgb(0, 0, 0); text-align: justify; font-style: inherit; font-weight: inherit;\"><br><\/span><\/p>\n<p><span style=\"color: rgb(0, 0, 0); text-align: justify; font-style: inherit; font-weight: inherit;\">La mayor\u00eda de los problemas se debe porque tienen un sistema de aire acondicionado de confort.&nbsp;<\/span><br><\/p>\n<p><span style=\"color: rgb(0, 0, 0); text-align: justify;\">Este tipo de equipo fue dise\u00f1ado para la personas, es decir para ajustar la temperatura donde cohabitan personas, donde opera pocas horas y no es constante, en ese aspecto es muy efectivo por que fue dise\u00f1ado precisamente para ello, sin embargo, no es el adecuado para un centro de datos ya que este, como anteriormente se mencion\u00f3 opera las 24 horas los 365 d\u00edas del a\u00f1o, con un sistema de confort al utilizarlo en este caso, se somete a un trabajo el cual no fue dise\u00f1ado para ello, en consecuencia, se debe dar mantenimiento de forma frecuente, da\u00f1o mayor de piezas mec\u00e1nicas, el\u00e9ctricas y electr\u00f3nicas y un eventual y prematuro da\u00f1o al equipo aire acondicionado.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-eb64a71 e-con-full e-flex e-con e-parent\" data-id=\"eb64a71\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-69b9228 elementor-widget elementor-widget-image\" data-id=\"69b9228\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"920\" height=\"508\" src=\"https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2020\/06\/control-de-temperatura-en-centros-de-datos-adviser.png\" class=\"attachment-large size-large wp-image-9658\" alt=\"control de temperatura en centros de datos\" srcset=\"https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2020\/06\/control-de-temperatura-en-centros-de-datos-adviser.png 920w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2020\/06\/control-de-temperatura-en-centros-de-datos-adviser-300x166.png 300w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2020\/06\/control-de-temperatura-en-centros-de-datos-adviser-768x424.png 768w\" sizes=\"(max-width: 920px) 100vw, 920px\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f66c7bd e-con-full e-flex e-con e-parent\" data-id=\"f66c7bd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2f39317 elementor-widget elementor-widget-heading\" data-id=\"2f39317\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><br><span style=\"font-family: Alatsi, sans-serif;font-size: 30px;text-align: justify\">\u00bfQu\u00e9 sistema de aire acondicionado es adecuado para tu centro de datos?<\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-16dd10f e-con-full e-flex e-con e-parent\" data-id=\"16dd10f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0bc32ef elementor-widget elementor-widget-text-editor\" data-id=\"0bc32ef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-style: inherit; font-weight: inherit; color: rgb(0, 0, 0); text-align: justify;\">Existe un sistema el cual est\u00e1 dise\u00f1ado espec\u00edficamente para cumplir con las exigencias de un centro de datos,&nbsp;<\/span><a href=\"https:\/\/www.itadviser.mx\/blog\/elegir-un-aire-acondicionado-de-precision\/\" style=\"font-style: inherit; font-weight: inherit; text-align: justify; background-color: rgb(255, 255, 255);\"><span style=\"font-weight: 700;\">Aire Acondicionado de Precisi\u00f3n<\/span><\/a><span style=\"font-style: inherit; font-weight: inherit; color: rgb(0, 0, 0); text-align: justify;\">.&nbsp;<\/span><br><\/p>\n<p><span style=\"color: rgb(0, 0, 0); text-align: justify;\">Este tipo de equipo trabaja de forma constante, contando con un sistema de redundancia incorporado, reduce la probabilidad de que exista paro en el equipo, mantiene un nivel \u00f3ptimo de temperatura y humedad, siendo sensible a los cambios en los par\u00e1metros que se tienen dentro del lugar, y solventando de manera eficiente los problemas sobre ellos.<\/span><\/p>\n<p><span style=\"color: rgb(0, 0, 0); text-align: justify;\">Con lo anterior, <b>\u00bfpor qu\u00e9 se opta por m\u00e1s por \u201cconfort\u201d que precisi\u00f3n?<\/b>, son varios factores, como desconocimiento, solvencia econ\u00f3mica y espacio en el lugar.<\/span><\/p><p><span style=\"color: rgb(0, 0, 0);\">Sin embargo existen soluciones de Aire Acondicionado de precisi\u00f3n adecuadas para las necesidades de las empresas tomando en cuenta la calidad-solvencia-alcance. Algunas de los fabricantes que aportan soluciones extraordinarias son<\/span><span style=\"color: rgb(0, 0, 0);\">&nbsp;<\/span><a href=\"https:\/\/www.itadviser.mx\/brand\/10-apc\" style=\"background-color: rgb(255, 255, 255); transition-property: all;\"><span style=\"font-weight: 700;\">APC<\/span><\/a><span style=\"color: rgb(0, 0, 0);\">&nbsp;<\/span><span style=\"color: rgb(0, 0, 0);\">y<\/span><span style=\"color: rgb(0, 0, 0);\">&nbsp;<\/span><a href=\"https:\/\/www.itadviser.mx\/brand\/11-vertiv\" style=\"background-color: rgb(255, 255, 255); transition-property: all;\"><span style=\"font-weight: 700;\">VERTIV<\/span><\/a><span style=\"color: rgb(0, 0, 0);\">, su experiencia en el mercado, su posicionamiento y sus a\u00f1os de experiencia, respaldan de manera segura y efectiva a sus equipos dentro de Data Center.<\/span><span style=\"color: rgb(0, 0, 0); text-align: justify;\"><br><\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8c3e95e e-con-full e-flex e-con e-parent\" data-id=\"8c3e95e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d837468 elementor-widget elementor-widget-image\" data-id=\"d837468\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"920\" height=\"508\" src=\"https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2020\/06\/control-de-temperatura-en-centros-de-datos-aire-acondicionado.png\" class=\"attachment-large size-large wp-image-9660\" alt=\"\" srcset=\"https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2020\/06\/control-de-temperatura-en-centros-de-datos-aire-acondicionado.png 920w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2020\/06\/control-de-temperatura-en-centros-de-datos-aire-acondicionado-300x166.png 300w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2020\/06\/control-de-temperatura-en-centros-de-datos-aire-acondicionado-768x424.png 768w\" sizes=\"(max-width: 920px) 100vw, 920px\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f7c4f16 e-con-full e-flex e-con e-parent\" data-id=\"f7c4f16\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-eebb279 elementor-widget elementor-widget-heading\" data-id=\"eebb279\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><br><span style=\"font-family: Alatsi, sans-serif;font-size: 30px;text-align: justify;font-weight: var( --e-global-typography-primary-font-weight )\">Buenas pr\u00e1cticas para lograr un control de temperatura eficiente en centros de datos<\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ca9744a e-con-full e-flex e-con e-parent\" data-id=\"ca9744a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3b1d525 elementor-widget elementor-widget-text-editor\" data-id=\"3b1d525\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-size: 12pt; font-style: inherit; font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); text-align: start;\">Lograr un <\/span><span style=\"font-size: 12pt; font-style: inherit; font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); text-align: start;\">control de temperatura en centros de datos<\/span><span style=\"font-size: 12pt; font-style: inherit; font-weight: inherit; font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); text-align: start;\"> no depende \u00fanicamente del tipo de aire acondicionado que se instale. Requiere una estrategia integral que combine dise\u00f1o t\u00e9rmico, monitoreo continuo, eficiencia energ\u00e9tica y mantenimiento especializado. Para \u00e1reas de infraestructura tecnol\u00f3gica, operaciones, ventas t\u00e9cnicas y tomadores de decisi\u00f3n, estos son los puntos clave a considerar:<\/span><\/p><p><span style=\"font-size: 12pt; font-style: inherit; font-weight: inherit; font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); text-align: start;\"><br><\/span><\/p>\n<p><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\"><b>1. Definir rangos operativos \u00f3ptimos de temperatura y humedad<\/b><\/span><\/p>\n<p><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\">Cada centro de datos debe operar dentro de rangos t\u00e9rmicos espec\u00edficos que garanticen la confiabilidad de los equipos de TI. Mantener una <\/span><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\">temperatura estable<\/span><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\"> y una <\/span><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\">humedad controlada<\/span><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\"> reduce riesgos como sobrecalentamiento, descargas electrost\u00e1ticas o condensaci\u00f3n. Una pol\u00edtica clara de <\/span><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\">gesti\u00f3n t\u00e9rmica en data centers<\/span><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\"> ayuda a estandarizar la operaci\u00f3n y a evitar ajustes improvisados que impacten el desempe\u00f1o.<\/span><\/p>\n<p><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\"><b>2. Implementar monitoreo t\u00e9rmico en tiempo real<\/b><\/span><\/p>\n<p><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\">El <\/span><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\">monitoreo ambiental en centros de datos<\/span><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\"> permite detectar variaciones de temperatura antes de que se conviertan en fallas cr\u00edticas. Sensores distribuidos en racks, pasillos fr\u00edos\/calientes y zonas cr\u00edticas brindan visibilidad operativa para una <\/span><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\">toma de decisiones basada en datos<\/span><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\">. Esto no solo mejora la continuidad del negocio, sino que tambi\u00e9n optimiza el uso del sistema de climatizaci\u00f3n.&nbsp;<\/span><\/p>\n<p><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\"><b>3. Optimizar la distribuci\u00f3n del aire (flujo de aire y contenci\u00f3n)<\/b><\/span><\/p>\n<p><span style=\"color: rgb(0, 0, 0); font-size: 12pt; text-align: start; font-family: &quot;Franklin Gothic Book&quot;, sans-serif;\">Un error com\u00fan en el control de temperatura en centros de datos es tener equipos de climatizaci\u00f3n potentes, pero una mala distribuci\u00f3n del aire. Estrategias como la <\/span><span style=\"color: rgb(0, 0, 0); font-size: 12pt; text-align: start; font-family: &quot;Franklin Gothic Book&quot;, sans-serif;\">separaci\u00f3n de pasillos fr\u00edos y calientes<\/span><span style=\"color: rgb(0, 0, 0); font-size: 12pt; text-align: start; font-family: &quot;Franklin Gothic Book&quot;, sans-serif;\">, la correcta orientaci\u00f3n de racks y el sellado de fugas de aire mejoran la eficiencia del enfriamiento. Esto se traduce en <\/span><span style=\"color: rgb(0, 0, 0); font-size: 12pt; text-align: start; font-family: &quot;Franklin Gothic Book&quot;, sans-serif;\">menor consumo energ\u00e9tico<\/span><span style=\"color: rgb(0, 0, 0); font-size: 12pt; text-align: start; font-family: &quot;Franklin Gothic Book&quot;, sans-serif;\"> y mayor aprovechamiento de la infraestructura existente.<\/span><\/p>\n<p><span style=\"color: rgb(0, 0, 0); font-size: 12pt; text-align: start; font-family: &quot;Franklin Gothic Book&quot;, sans-serif;\"><b>4. Dise\u00f1ar con enfoque en eficiencia energ\u00e9tica<\/b><\/span><\/p>\n<p><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\">El enfriamiento representa uno de los mayores costos operativos en un centro de datos. Un <\/span><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\">control de temperatura en centros de datos<\/span><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\"> bien planeado impacta directamente en el <\/span><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\">PUE (Power Usage Effectiveness)<\/span><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\">, indicador clave para la eficiencia energ\u00e9tica. Invertir en soluciones de climatizaci\u00f3n adecuadas y en un dise\u00f1o t\u00e9rmico correcto no solo protege los equipos, sino que tambi\u00e9n reduce costos de operaci\u00f3n a mediano y largo plazo.<\/span><\/p>\n<p><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\"><b>5. Mantenimiento preventivo y planeaci\u00f3n de crecimiento<\/b><\/span><\/p>\n<p><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\">El control t\u00e9rmico no es est\u00e1tico. A medida que el centro de datos crece en capacidad de c\u00f3mputo, tambi\u00e9n aumenta la densidad t\u00e9rmica. Por ello, es fundamental contar con <\/span><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\">planes de mantenimiento preventivo<\/span><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\"> y una <\/span><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\">planeaci\u00f3n de capacidad de enfriamiento<\/span><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\"> alineada al crecimiento del negocio. Esto permite anticipar cuellos de botella t\u00e9rmicos antes de que afecten la operaci\u00f3n.<\/span><\/p><p><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\"><br><\/span><\/p><p><span style=\"font-style: inherit; font-weight: inherit; white-space-collapse: preserve; color: rgb(13, 13, 13); font-family: S\u00f6hne, ui-sans-serif, system-ui, -apple-system, &quot;Segoe UI&quot;, Roboto, Ubuntu, Cantarell, &quot;Noto Sans&quot;, sans-serif, &quot;Helvetica Neue&quot;, Arial, &quot;Apple Color Emoji&quot;, &quot;Segoe UI Emoji&quot;, &quot;Segoe UI Symbol&quot;, &quot;Noto Color Emoji&quot;;\">Te invito a visitar la tienda de <a href=\"https:\/\/www.itadviser.mx\/\" style=\"transition-property: all;\"><span style=\"font-weight: 700;\">Adviser<\/span><\/a> donde tenemos<\/span><a href=\"https:\/\/www.itadviser.mx\/blog\/mantenimiento-a-aire-acondicionado-de-precision\/\" style=\"background-color: rgb(255, 255, 255); transition-property: all; font-style: inherit; font-weight: inherit; white-space-collapse: preserve; font-family: S\u00f6hne, ui-sans-serif, system-ui, -apple-system, &quot;Segoe UI&quot;, Roboto, Ubuntu, Cantarell, &quot;Noto Sans&quot;, sans-serif, &quot;Helvetica Neue&quot;, Arial, &quot;Apple Color Emoji&quot;, &quot;Segoe UI Emoji&quot;, &quot;Segoe UI Symbol&quot;, &quot;Noto Color Emoji&quot;;\"> <span style=\"font-weight: 700;\">las mejores soluciones de climatizaci\u00f3n<\/span><\/a><span style=\"font-style: inherit; font-weight: inherit; white-space-collapse: preserve; color: rgb(13, 13, 13); font-family: S\u00f6hne, ui-sans-serif, system-ui, -apple-system, &quot;Segoe UI&quot;, Roboto, Ubuntu, Cantarell, &quot;Noto Sans&quot;, sans-serif, &quot;Helvetica Neue&quot;, Arial, &quot;Apple Color Emoji&quot;, &quot;Segoe UI Emoji&quot;, &quot;Segoe UI Symbol&quot;, &quot;Noto Color Emoji&quot;;\"> para tener un mejor control de temperatura en centros de datos. Contamos con personal altamente calificado que te dar\u00e1 la asesor\u00eda y el respaldo t\u00e9cnico que necesitas para la implementaci\u00f3n de nuevos proyectos y la modernizaci\u00f3n de tu infraestructura tecnol\u00f3gica.<\/span><span style=\"font-family: &quot;Franklin Gothic Book&quot;, sans-serif; color: rgb(0, 0, 0); font-size: 12pt; text-align: start;\"><br><\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1fe4985 e-con-full e-flex e-con e-parent\" data-id=\"1fe4985\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5c66f1e elementor-widget elementor-widget-text-editor\" data-id=\"5c66f1e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p style=\"font-size: 16px; font-style: normal; font-weight: 400;\"><span style=\"color: #0d0d0d; font-family: S\u00f6hne, ui-sans-serif, system-ui, -apple-system, 'Segoe UI', Roboto, Ubuntu, Cantarell, 'Noto Sans', sans-serif, 'Helvetica Neue', Arial, 'Apple Color Emoji', 'Segoe UI Emoji', 'Segoe UI Symbol', 'Noto Color Emoji';\"><span style=\"white-space-collapse: preserve;\"><span style=\"font-weight: bold;\">S\u00edguenos en nuestras redes sociales:<\/span><\/span><\/span><\/p><p style=\"font-size: 16px; font-style: normal; font-weight: 400;\"><a style=\"background-color: #ffffff; transition-property: all; font-style: inherit; font-weight: inherit; font-family: var( --e-global-typography-text-font-family ), Sans-serif; text-align: justify;\" href=\"https:\/\/www.facebook.com\/p\/IT-Adviser-100063671183156\/\" target=\"_blank\" rel=\"noopener\">Facebook<\/a><span style=\"font-style: inherit; font-weight: inherit; color: var( --e-global-color-text ); font-family: var( --e-global-typography-text-font-family ), Sans-serif; text-align: justify;\">\u00a0&#8211;\u00a0<\/span><a style=\"background-color: #ffffff; transition-property: all; font-style: inherit; font-weight: inherit; font-family: var( --e-global-typography-text-font-family ), Sans-serif; text-align: justify;\" href=\"https:\/\/www.instagram.com\/it_adviser_\/\" target=\"_blank\" rel=\"noopener\">Instagram<\/a><span style=\"font-style: inherit; font-weight: inherit; color: var( --e-global-color-text ); font-family: var( --e-global-typography-text-font-family ), Sans-serif; text-align: justify;\">\u00a0&#8211;\u00a0<\/span><a style=\"background-color: #ffffff; transition-property: all; font-style: inherit; font-weight: inherit; font-family: var( --e-global-typography-text-font-family ), Sans-serif; text-align: justify;\" href=\"https:\/\/www.linkedin.com\/company\/itadvisersadecv\/\" target=\"_blank\" rel=\"noopener\">LinkedIn<\/a><span style=\"font-style: inherit; font-weight: inherit; color: var( --e-global-color-text ); font-family: var( --e-global-typography-text-font-family ), Sans-serif; text-align: justify;\">\u00a0&#8211;\u00a0<\/span><a style=\"background-color: #ffffff; transition-property: all; font-style: inherit; font-weight: inherit; font-family: var( --e-global-typography-text-font-family ), Sans-serif; text-align: justify;\" href=\"https:\/\/www.itadviser.mx\/\">Ecommerce<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-445c4ce e-con-full e-flex e-con e-parent\" data-id=\"445c4ce\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-138e1c9 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"138e1c9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e532314 e-flex e-con-boxed e-con e-parent\" data-id=\"e532314\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d86ff12 elementor-widget elementor-widget-wp-widget-nav_menu\" data-id=\"d86ff12\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"wp-widget-nav_menu.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h5>Men\u00fa<\/h5><nav class=\"menu-it-adviser-container\" aria-label=\"Men\u00fa\"><ul id=\"menu-it-adviser\" class=\"menu\"><li id=\"menu-item-805\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-home menu-item-805\"><a href=\"https:\/\/www.itadviser.mx\/blog\/\" class=\"menu-link\">INICIO<\/a><\/li>\n<li id=\"menu-item-12980\" class=\"menu-item menu-item-type-taxonomy menu-item-object-category menu-item-12980\"><a href=\"https:\/\/www.itadviser.mx\/blog\/conectividad\/\" class=\"menu-link\">CONECTIVIDAD<\/a><\/li>\n<li id=\"menu-item-511\" class=\"menu-item menu-item-type-taxonomy menu-item-object-category menu-item-511\"><a href=\"https:\/\/www.itadviser.mx\/blog\/electrico\/\" class=\"menu-link\">EL\u00c9CTRICO<\/a><\/li>\n<li id=\"menu-item-13013\" class=\"menu-item menu-item-type-taxonomy menu-item-object-category menu-item-13013\"><a href=\"https:\/\/www.itadviser.mx\/blog\/aire-acondicionado\/\" class=\"menu-link\">CLIMA<\/a><\/li>\n<li id=\"menu-item-510\" class=\"menu-item menu-item-type-taxonomy menu-item-object-category menu-item-510\"><a href=\"https:\/\/www.itadviser.mx\/blog\/seguridad\/\" class=\"menu-link\">SEGURIDAD<\/a><\/li>\n<li id=\"menu-item-1689\" class=\"menu-item menu-item-type-taxonomy menu-item-object-category menu-item-1689\"><a href=\"https:\/\/www.itadviser.mx\/blog\/audio-y-video\/\" class=\"menu-link\">PRO A\/V<\/a><\/li>\n<li id=\"menu-item-12963\" class=\"menu-item menu-item-type-taxonomy menu-item-object-category menu-item-12963\"><a href=\"https:\/\/www.itadviser.mx\/blog\/monitoreo\/\" class=\"menu-link\">MONITOREO<\/a><\/li>\n<li id=\"menu-item-13016\" class=\"menu-item menu-item-type-taxonomy menu-item-object-category menu-item-has-children menu-item-13016\"><a href=\"https:\/\/www.itadviser.mx\/blog\/especiales-it\/\" aria-expanded=\"false\" class=\"menu-link\">ESPECIALES IT<span role=\"button\" class=\"dropdown-menu-toggle ast-header-navigation-arrow\" tabindex=\"0\" aria-expanded=\"false\" aria-label=\"Alternar el submen\u00fa ESPECIALES IT\" aria-haspopup=\"true\"><\/span><\/a>\n<ul class=\"sub-menu\">\n\t<li id=\"menu-item-1709\" class=\"menu-item menu-item-type-taxonomy menu-item-object-category menu-item-1709\"><a href=\"https:\/\/www.itadviser.mx\/blog\/especiales-it\/aplicativos-moviles\/\" class=\"menu-link\">APLICATIVOS M\u00d3VILES<\/a><\/li>\n\t<li id=\"menu-item-6337\" class=\"menu-item menu-item-type-taxonomy menu-item-object-category menu-item-6337\"><a href=\"https:\/\/www.itadviser.mx\/blog\/especiales-it\/marketing\/\" class=\"menu-link\">MARKETING<\/a><\/li>\n<\/ul>\n<\/li>\n<li id=\"menu-item-12956\" class=\"menu-item menu-item-type-custom menu-item-object-custom menu-item-12956\"><a href=\"https:\/\/www.itadviser.mx\/\" class=\"menu-link\">ECOMMERCE<\/a><\/li>\n<li id=\"menu-item-509\" class=\"menu-item menu-item-type-taxonomy menu-item-object-category menu-item-has-children menu-item-509\"><a href=\"https:\/\/www.itadviser.mx\/blog\/servicios\/\" aria-expanded=\"false\" class=\"menu-link\">SERVICIOS<span role=\"button\" class=\"dropdown-menu-toggle ast-header-navigation-arrow\" tabindex=\"0\" aria-expanded=\"false\" aria-label=\"Alternar el submen\u00fa SERVICIOS\" aria-haspopup=\"true\"><\/span><\/a>\n<ul class=\"sub-menu\">\n\t<li id=\"menu-item-504\" class=\"menu-item menu-item-type-taxonomy menu-item-object-category menu-item-504\"><a href=\"https:\/\/www.itadviser.mx\/blog\/mantenimiento\/\" class=\"menu-link\">MANTENIMIENTO<\/a><\/li>\n<\/ul>\n<\/li>\n<li id=\"menu-item-12957\" class=\"menu-item menu-item-type-custom menu-item-object-custom menu-item-12957\"><a href=\"https:\/\/www.itadviser.com.mx\/\" class=\"menu-link\" target=\"_blank\" rel=\"noopener\">PROYECTOS<\/a><\/li>\n<li id=\"menu-item-1078\" class=\"menu-item menu-item-type-post_type menu-item-object-page current_page_parent menu-item-1078\"><a href=\"https:\/\/www.itadviser.mx\/blog\/blog-sobre-infraestructura-tecnologica\/\" class=\"menu-link\">ENTRADAS BLOG<\/a><\/li>\n<li id=\"menu-item-1088\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-1088\"><a href=\"https:\/\/www.itadviser.mx\/blog\/contacto-blog-de-it-adviser\/\" class=\"menu-link\">CONTACTO<\/a><\/li>\n<\/ul><\/nav>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-75acf3f e-flex e-con-boxed e-con e-parent\" data-id=\"75acf3f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-08d5818 elementor-widget elementor-widget-shortcode\" data-id=\"08d5818\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n\t\t\t<form id=\"sib_signup_form_1\" method=\"post\" class=\"sib_signup_form\">\n\t\t\t\t<div class=\"sib_loader\" style=\"display:none;\"><img\n\t\t\t\t\t\t\tsrc=\"https:\/\/www.itadviser.mx\/blog\/wp-includes\/images\/spinner.gif\" alt=\"loader\"><\/div>\n\t\t\t\t<input type=\"hidden\" name=\"sib_form_action\" value=\"subscribe_form_submit\">\n\t\t\t\t<input type=\"hidden\" name=\"sib_form_id\" value=\"1\">\n                <input type=\"hidden\" name=\"sib_form_alert_notice\" value=\"Por favor, completa este campo.\">\n                <input type=\"hidden\" name=\"sib_form_invalid_email_notice\" value=\"Por favor, escribe un email v\u00e1lido.\">\n                <input type=\"hidden\" name=\"sib_security\" value=\"1663cd0f24\">\n\t\t\t\t<div class=\"sib_signup_box_inside_1\">\n\t\t\t\t\t<div style=\"\/*display:none*\/\" class=\"sib_msg_disp\">\n\t\t\t\t\t<\/div>\n                    \t\t\t\t\t<style>\n  :root{\n    --bg: #0b0f0d;\n    --panel: #0f1512;\n    --text: #e7f0ea;\n    --muted: #97a3a0;\n    --line: #22302a;\n    --green: #22c55e;\n    --green2:#16a34a;\n    --danger:#ef4444;\n    --shadow: 0 12px 30px rgba(0,0,0,.35);\n    --radius: 14px;\n  }\n\n  .sib-form-ux{\n    width: min(420px, 100%);\n    background: linear-gradient(180deg, rgba(34,197,94,.08), transparent 55%), var(--panel);\n    border: 1px solid var(--line);\n    border-radius: calc(var(--radius) + 2px);\n    padding: 18px;\n    box-shadow: var(--shadow);\n    font-family: system-ui, -apple-system, Segoe UI, Roboto, Arial, sans-serif;\n    color: var(--text);\n  }\n\n  .sib-form-ux .sib-title{\n    margin: 0 0 6px 0;\n    font-size: 18px;\n    font-weight: 700;\n    letter-spacing: .2px;\n  }\n\n  .sib-form-ux .sib-subtitle{\n    margin: 0 0 14px 0;\n    color: var(--muted);\n    font-size: 13px;\n    line-height: 1.35;\n  }\n\n  .sib-grid{\n    display: grid;\n    grid-template-columns: 1fr;\n    gap: 12px;\n  }\n\n  .sib-field{\n    display: grid;\n    gap: 7px;\n  }\n\n  .sib-label{\n    font-size: 12px;\n    color: var(--muted);\n    letter-spacing: .35px;\n    text-transform: uppercase;\n  }\n\n  .sib-label .req{\n    color: var(--green);\n    font-weight: 700;\n    margin-left: 4px;\n  }\n\n  .sib-input{\n    width: 100%;\n    box-sizing: border-box;\n    padding: 12px 12px;\n    border-radius: var(--radius);\n    border: 1px solid var(--line);\n    background: rgba(0,0,0,.25);\n    color: var(--text);\n    outline: none;\n    transition: border-color .2s ease, box-shadow .2s ease, transform .05s ease;\n  }\n\n  .sib-input::placeholder{\n    color: rgba(151,163,160,.7);\n  }\n\n  .sib-input:focus{\n    border-color: rgba(34,197,94,.85);\n    box-shadow: 0 0 0 4px rgba(34,197,94,.18);\n  }\n\n  .sib-input:required:invalid:not(:placeholder-shown){\n    border-color: rgba(239,68,68,.9);\n    box-shadow: 0 0 0 4px rgba(239,68,68,.12);\n  }\n\n  .sib-help{\n    margin: 0;\n    color: rgba(151,163,160,.92);\n    font-size: 12px;\n    line-height: 1.4;\n  }\n\n  .sib-btn{\n    width: 100%;\n    border: 0;\n    cursor: pointer;\n    padding: 12px 14px;\n    border-radius: var(--radius);\n    color: #07110b;\n    font-weight: 800;\n    letter-spacing: .2px;\n    background: linear-gradient(180deg, var(--green), var(--green2));\n    box-shadow: 0 10px 18px rgba(34,197,94,.18);\n    transition: transform .08s ease, filter .2s ease, box-shadow .2s ease;\n  }\n\n  .sib-btn:hover{\n    filter: brightness(1.05);\n    box-shadow: 0 12px 22px rgba(34,197,94,.22);\n  }\n\n  .sib-btn:active{\n    transform: translateY(1px);\n  }\n\n  .sib-legal{\n    margin: 10px 2px 0 2px;\n    font-size: 12px;\n    color: rgba(151,163,160,.85);\n    line-height: 1.35;\n  }\n\n  .sib-confirm-note{\n    margin: 10px 2px 0 2px;\n    color: rgba(231,240,234,.92);\n    font-size: 12px;\n    line-height: 1.5;\n  }\n\n  .sib-legal a{\n    color: rgba(34,197,94,.95);\n    text-decoration: none;\n    border-bottom: 1px dashed rgba(34,197,94,.45);\n  }\n\n  .sib-legal a:hover{\n    border-bottom-style: solid;\n  }\n\n  @media (min-width: 520px){\n    .sib-grid{\n      grid-template-columns: 1fr 1fr;\n    }\n    .sib-field.email,\n    .sib-field.company,\n    .sib-field.phone,\n    .sib-actions{\n      grid-column: 1 \/ -1;\n    }\n  }\n<\/style>\n\n<h3 class=\"sib-title\">Recibe conocimiento y novedades en nuestros correos<\/h3>\n<p class=\"sib-subtitle\">Te enviaremos un correo para confirmar tu registro y activar tu suscripcion.<\/p>\n\n<div class=\"sib-grid\">\n  <div class=\"sib-field email\">\n    <label class=\"sib-label\" for=\"sib-email\">E-mail <span class=\"req\">*<\/span><\/label>\n    <input id=\"sib-email\" type=\"email\" class=\"sib-input\" name=\"email\" required=\"required\" placeholder=\"tucorreo@empresa.com\">\n  <\/div>\n\n  <div class=\"sib-field\">\n    <label class=\"sib-label\" for=\"sib-firstname\">Nombre <span class=\"req\">*<\/span><\/label>\n    <input id=\"sib-firstname\" type=\"text\" class=\"sib-input\" name=\"FIRSTNAME\" required=\"required\" placeholder=\"Jose\">\n  <\/div>\n\n  <div class=\"sib-field\">\n    <label class=\"sib-label\" for=\"sib-lastname\">Apellido <span class=\"req\">*<\/span><\/label>\n    <input id=\"sib-lastname\" type=\"text\" class=\"sib-input\" name=\"LASTNAME\" required=\"required\" placeholder=\"Lopez\">\n  <\/div>\n\n  <div class=\"sib-field company\">\n    <label class=\"sib-label\" for=\"sib-company\">Empresa <span class=\"req\">*<\/span><\/label>\n    <input id=\"sib-company\" type=\"text\" class=\"sib-input\" name=\"company\" required=\"required\" placeholder=\"Nombre de tu empresa\">\n  <\/div>\n\n  <div class=\"sib-field phone\">\n    <label class=\"sib-label\" for=\"sib-phone\">Telefono <span class=\"req\">*<\/span><\/label>\n    <input id=\"sib-phone\" type=\"tel\" class=\"sib-input\" name=\"phone\" required=\"required\" pattern=\"[0-9]{10}\" placeholder=\"5512345678\">\n    <p class=\"sib-help\">Captura 10 digitos en formato Mexico.<\/p>\n  <\/div>\n\n  <div class=\"sib-actions\">\n    <input type=\"submit\" class=\"sib-btn\" value=\"Suscribirme\">\n    <p class=\"sib-confirm-note\">Despues de suscribirte, revisa tu correo y confirma desde ahi para activar tu registro.<\/p>\n    <div class=\"sib-legal\">\n      Al suscribirte aceptas recibir comunicaciones. Puedes darte de baja cuando quieras.\n      <!-- Si tienes URL de aviso de privacidad, ponla aqui -->\n      &lt;!-- <a href=\"\/content\/2-codigos-y-Politicas\">Aviso de privacidad<\/a> --&gt;\n    <\/div>\n  <\/div>\n<\/div>\t\t\t\t<\/div>\n\t\t\t<\/form>\n\t\t\t<style>\n\t\t\t\tform#sib_signup_form_1 p.sib-alert-message {\n    padding: 6px 12px;\n    margin-bottom: 20px;\n    border: 1px solid transparent;\n    border-radius: 4px;\n    -webkit-box-sizing: border-box;\n    -moz-box-sizing: border-box;\n    box-sizing: border-box;\n}\nform#sib_signup_form_1 p.sib-alert-message-error {\n    background-color: #f2dede;\n    border-color: #ebccd1;\n    color: #a94442;\n}\nform#sib_signup_form_1 p.sib-alert-message-success {\n    background-color: #dff0d8;\n    border-color: #d6e9c6;\n    color: #3c763d;\n}\nform#sib_signup_form_1 p.sib-alert-message-warning {\n    background-color: #fcf8e3;\n    border-color: #faebcc;\n    color: #8a6d3b;\n}\n\t\t\t<\/style>\n\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-db6d003 e-flex e-con-boxed e-con e-parent\" data-id=\"db6d003\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Zabdiel Olvera | Asesor comercial en Adviser\u00a0 Importancia de tener un buen control de temperatura en centros de datos Los equipos electr\u00f3nicos dado su operatividad y su dise\u00f1o, trabajan en un cierto rango de temperatura el cual permite que opere de forma adecuada, sin embargo al salirse de ese par\u00e1metro, puede presentar problemas de operaci\u00f3n, [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":true,"template":"elementor_canvas","format":"standard","meta":{"_uag_custom_page_level_css":"","_monsterinsights_skip_tracking":false,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[22],"tags":[139,225,38,23],"class_list":["post-251","post","type-post","status-publish","format-standard","hentry","category-aire-acondicionado","tag-aire-acondicionado-de-precision","tag-aire-acondicionado-de-confort","tag-centro-de-datos","tag-temperatura"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false},"uagb_author_info":{"display_name":"Zabdiel Olvera","author_link":"https:\/\/www.itadviser.mx\/blog\/author\/zabdiel-olvera\/"},"uagb_comment_info":0,"uagb_excerpt":"Zabdiel Olvera | Asesor comercial en Adviser\u00a0 Importancia de tener un buen control de temperatura en centros de datos Los equipos electr\u00f3nicos dado su operatividad y su dise\u00f1o, trabajan en un cierto rango de temperatura el cual permite que opere de forma adecuada, sin embargo al salirse de ese par\u00e1metro, puede presentar problemas de operaci\u00f3n,&hellip;","_links":{"self":[{"href":"https:\/\/www.itadviser.mx\/blog\/wp-json\/wp\/v2\/posts\/251","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.itadviser.mx\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.itadviser.mx\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.itadviser.mx\/blog\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.itadviser.mx\/blog\/wp-json\/wp\/v2\/comments?post=251"}],"version-history":[{"count":0,"href":"https:\/\/www.itadviser.mx\/blog\/wp-json\/wp\/v2\/posts\/251\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.itadviser.mx\/blog\/wp-json\/wp\/v2\/media?parent=251"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.itadviser.mx\/blog\/wp-json\/wp\/v2\/categories?post=251"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.itadviser.mx\/blog\/wp-json\/wp\/v2\/tags?post=251"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}