{"id":4048,"date":"2024-05-31T10:00:00","date_gmt":"2024-05-31T15:00:00","guid":{"rendered":"https:\/\/www.itadviser.mx\/blog\/?p=4048"},"modified":"2025-02-06T12:23:51","modified_gmt":"2025-02-06T18:23:51","slug":"normativas-plantas-energia-electrica","status":"publish","type":"post","link":"https:\/\/www.itadviser.mx\/blog\/normativas-plantas-energia-electrica\/","title":{"rendered":"Especificaciones Clave de la NOM-J-467-1989 en Plantas Generadoras de Energ\u00eda El\u00e9ctrica en M\u00e9xico"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"4048\" class=\"elementor elementor-4048\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b031006 e-con-full e-flex e-con e-parent\" data-id=\"b031006\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-446da72 elementor-widget elementor-widget-image\" data-id=\"446da72\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"390\" src=\"https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2024\/05\/NEWSLETTER-1024x390.png\" class=\"attachment-large size-large wp-image-4051\" alt=\"Normativas NOM-J-467-1989 Plantas Generadoras de Energ\u00eda El\u00e9ctrica\" srcset=\"https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2024\/05\/NEWSLETTER-1024x390.png 1024w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2024\/05\/NEWSLETTER-300x114.png 300w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2024\/05\/NEWSLETTER-768x292.png 768w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2024\/05\/NEWSLETTER-1536x584.png 1536w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2024\/05\/NEWSLETTER-2048x779.png 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-27fbfe9 elementor-widget elementor-widget-heading\" data-id=\"27fbfe9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><br>Por: Zabdiel Olvera | Asesor Comercial IT Adviser<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9e58afa e-con-full e-flex e-con e-parent\" data-id=\"9e58afa\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0c33a2e elementor-widget elementor-widget-heading\" data-id=\"0c33a2e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><br>Seguridad y eficiencia con la NOM-J-467-1989 en Plantas Generadoras de Energ\u00eda El\u00e9ctrica<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f765a73 e-con-full e-flex e-con e-parent\" data-id=\"f765a73\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4676e18 elementor-widget elementor-widget-text-editor\" data-id=\"4676e18\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>En M\u00e9xico, el funcionamiento de las plantas generadoras de energ\u00eda el\u00e9ctrica de emergencia est\u00e1 regulado por un conjunto de normativas establecidas por el gobierno federal, las cuales son publicadas en el Diario Oficial de la Federaci\u00f3n (DOF) conforme la Norma Oficial Mexicana NOM-J-467-1989. Estas normas est\u00e1n dise\u00f1adas para garantizar la seguridad, eficiencia y cumplimiento en la operaci\u00f3n en situaciones cr\u00edticas como cortes de energ\u00eda o desastres naturales.<\/p>\n<p>La&nbsp;<span style=\"color: #0d0d0d; font-family: ui-sans-serif, -apple-system, system-ui, 'Segoe UI', Roboto, Ubuntu, Cantarell, 'Noto Sans', sans-serif, Helvetica, 'Apple Color Emoji', Arial, 'Segoe UI Emoji', 'Segoe UI Symbol'; text-align: start; white-space-collapse: preserve; background-color: #f4f4f4;\">NOM-J-467-1989 en plantas generadoras de energ\u00eda el\u00e9ctrica<\/span>&nbsp;establece una serie de requisitos de construcci\u00f3n, instalaci\u00f3n, operaci\u00f3n, <a href=\"https:\/\/www.itadviser.mx\/blog\/mantenimiento-a-plantas-de-emergencia\/\"><b>mantenimiento<\/b><\/a>, as\u00ed como los m\u00e9todos de prueba que deben cumplir las plantas generadoras de energ\u00eda el\u00e9ctrica de combusti\u00f3n interna.<\/p>\n<p>Algunas de las especificaciones establecidas en la norma, por mencionar algunas, son:<\/p>\n<ul>\n<li><b>Cantidad m\u00ednima de combustible almacenado en tanque de d\u00eda.<br><\/b>La cantidad m\u00ednima de combustible almacenado para la operaci\u00f3n debe ser suficiente para que la misma pueda operar a su carga nominal en forma continua sin que sea necesario el recargar combustible en su propio tanque.<\/li>\n<\/ul>\n<ul>\n<li>&nbsp;<b>Temperatura<\/b><br>La planta debe contar con los elementos necesarios para mantenerse a una temperatura que permita al motor arranque inmediato, siendo la m\u00ednima para el motor de 55\u00b0C y para el agua de enfriamiento de 45\u00b0C.<\/li>\n<\/ul>\n<ul>\n<li><b>Potencia de sobrecarga.<br><\/b>Se debe tener la potencia de sobrecarga suficiente para suministrar el 10% adicional a la potencia continua durante el periodo de tiempo que dure la falla, as\u00ed como el tiempo de respuesta indicado para tomar la carga, estabilizar la frecuencia y la tensi\u00f3n a partir del momento en que se interrumpa la energ\u00eda de suministro normal.<\/li>\n<\/ul>\n<ul>\n<li><b>Gobernadores de velocidad.<br><\/b>Los gobernadores de velocidad deben mantener una amplitud de banda de la frecuencia nominal para cualquier carga constante o demandas pico, para sistemas de c\u00f3mputo y transmisores de comunicaci\u00f3n, no debe exceder del 1% de la frecuencia nominal, para hospitales, telecomunicaciones y equipos de procesamiento de datos el 1.5%, para sistemas de alumbrado, bombas, ventiladores, malacates y establecimientos comerciales en general el 4%, para prop\u00f3sitos generales de alumbrado, aplicaciones industriales y construcci\u00f3n el 5% de la frecuencia nominal.<\/li>\n<\/ul>\n<ul>\n<li><b>Duraci\u00f3n de los intentos del motor de arranque.<br><\/b>Para m\u00e1quinas motrices del ciclo Otto o Diesel, el tiempo y la duraci\u00f3n de los intentos de arranque autom\u00e1ticas y semiautom\u00e1ticas, debe consistir de un per\u00edodo de 10 a 15 s, seguido de un per\u00edodo de reposo de 10 a 15 s de duraci\u00f3n y como m\u00ednimo debe tener tres intentos de arranque el sistema autom\u00e1tico.<\/li>\n<\/ul>\n<ul>\n<li><b>Tablero de control.<br><\/b>Debe contener como m\u00ednimo, m\u00f3dulo de \u00abarranque-paro\u00bb y protecciones, selector \u00abmanual-fuera-autom\u00e1tico\u00bb, alarmas visuales, mediciones el\u00e9ctricas, \u00abbot\u00f3n o interruptor de prueba\u00bb, para verificaci\u00f3n de sistema, \u00abbot\u00f3n o interruptor de restablecimiento\u00bb, o desbloqueo.<\/li>\n<\/ul>\n<ul>\n<li><b>&nbsp;Marcado<br><\/b>Debe llevar una placa de datos marcada en forma indeleble, legible e inviolable con los siguientes datos m\u00ednimos.<br>&#8211; Nombre o raz\u00f3n social del fabricante.<br>&#8211; S\u00edmbolo de autorizaci\u00f3n para la fabricaci\u00f3n, venta y uso NOM.<br>&#8211; La leyenda \u00abHECHO EN MEXICO\u00bb.<br>&#8211; Masa neta de la planta generadora de energ\u00eda el\u00e9ctrica de emergencia.<br>&#8211; Marca -Modelo-Serie-.<br>&#8211; Fecha de ensamble.<br>&#8211; Tensi\u00f3n de operaci\u00f3n.366<br>&#8211; Frecuencia.<br>&#8211; N\u00famero de fases.<br>&#8211; Velocidad en revoluciones por minuto.<br>&#8211; Modelo del motor y modelo del generador.<br>&#8211; N\u00famero de serie del motor y n\u00famero de serie del generador.<br>&#8211; Capacidad de emergencia indicando la altura sobre el nivel del mar.<br>&#8211; Capacidad de sobrecarga en un per\u00edodo mientras dure la interrupci\u00f3n de suministro normal no importando el tiempo que \u00e9sta persista.<br>&#8211; Capacidad contin\u00faa indicando la altura sobre el nivel del mar.<br>&#8211; Temperatura m\u00e1xima de operaci\u00f3n para el motor de combusti\u00f3n interna y el generador.<\/li>\n<\/ul>\n<h3><b>&nbsp;<\/b><\/h3>\n<h3 style=\"font-style: normal; font-weight: var( --e-global-typography-primary-font-weight ); color: rgb(0, 0, 0); line-height: 1.3em; font-family: var( --e-global-typography-primary-font-family ), Sans-serif; text-align: start;\">Normativas adicionales a la NOM-J-467-1989<\/h3>\n<div><b><span style=\"font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-size: 1rem;\">&nbsp;<\/span><\/b><\/div>\n<p>Adem\u00e1s de la aplicaci\u00f3n de la NOM-J-467-1989 en&nbsp;<span style=\"font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight ); font-size: 1rem;\">plantas generadoras de energ\u00eda el\u00e9ctrica de emergencia<\/span><span style=\"font-style: inherit; font-weight: inherit; font-family: var( --e-global-typography-text-font-family ), Sans-serif;\">, existen otras normativas que complementan los requisitos establecidos para las mismas. Algunas de estas normativas son:<\/span><\/p>\n<p>NOM-D-6 Motores para uso automotriz no turbo-cargados con encendido por buj\u00eda o di\u00e9sel &#8211; M\u00e9todo de prueba.<\/p>\n<p>NOM-J-122 Productos el\u00e9ctricos &#8211; Acumuladores el\u00e9ctricos tipo plomo-\u00e1cido utilizados en veh\u00edculos automotores.<\/p>\n<p>NOM-J-153 Clasificaci\u00f3n de materiales aislantes.<\/p>\n<p>NOM-J-157 Barnices aislantes para la protecci\u00f3n adicional de aparatos.<\/p>\n<p>NOM-J-171 Acumuladores el\u00e9ctricos industriales tipo plomo-\u00e1cido.<\/p>\n<p>NOM-J-201 Bater\u00edas alcalinas de n\u00edquel-cadmio de tipo semi abierto con envase de pl\u00e1stico.<\/p>\n<p>NOM-J-445 Productos el\u00e9ctricos &#8211; Cargadores de bater\u00edas de uso automotriz.<\/p>\n<p><\/p>\n<p>Como podr\u00e1s notar en la&nbsp;<span style=\"font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight ); font-size: 1rem;\">NOM-J-467-1989 en&nbsp;<\/span><span style=\"font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight ); font-size: 1rem;\">plantas generadoras de energ\u00eda el\u00e9ctrica,&nbsp;<\/span><span style=\"font-style: inherit; font-weight: inherit; font-family: var( --e-global-typography-text-font-family ), Sans-serif;\">existen bastantes especificaciones que se deben cumplir para comercializar este tipo de equipos. \u00bfEst\u00e1s interesado en adquirir una planta de generaci\u00f3n el\u00e9ctrica?, contacta con nosotros y verifica disponibilidad, con gusto uno de nuestros especialistas estar\u00e1 para asesorarte.<\/span><\/p>\n<p><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7271eb1 e-grid e-con-full e-con e-parent\" data-id=\"7271eb1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7435851 elementor-widget elementor-widget-image\" data-id=\"7435851\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1024\" height=\"708\" src=\"https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2024\/05\/NOM-J-467-1989-plantas-de-energia-electrica-3-1024x708.jpg\" class=\"attachment-large size-large wp-image-4086\" alt=\"NOM-J-467-1989 en Plantas Generadoras de Energ\u00eda El\u00e9ctrica\" srcset=\"https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2024\/05\/NOM-J-467-1989-plantas-de-energia-electrica-3-1024x708.jpg 1024w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2024\/05\/NOM-J-467-1989-plantas-de-energia-electrica-3-300x207.jpg 300w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2024\/05\/NOM-J-467-1989-plantas-de-energia-electrica-3-768x531.jpg 768w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2024\/05\/NOM-J-467-1989-plantas-de-energia-electrica-3-1536x1061.jpg 1536w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2024\/05\/NOM-J-467-1989-plantas-de-energia-electrica-3-2048x1415.jpg 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-653796c elementor-widget elementor-widget-image\" data-id=\"653796c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1024\" height=\"509\" src=\"https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2024\/05\/NOM-J-467-1989-en-plantas-de-energia-electrica-de-emergencia-1024x509.jpg\" class=\"attachment-large size-large wp-image-4067\" alt=\"NOM-J-467-1989 en plantas de energi\u0301a ele\u0301ctrica de emergencia en M\u00e9xico\" srcset=\"https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2024\/05\/NOM-J-467-1989-en-plantas-de-energia-electrica-de-emergencia-1024x509.jpg 1024w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2024\/05\/NOM-J-467-1989-en-plantas-de-energia-electrica-de-emergencia-300x149.jpg 300w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2024\/05\/NOM-J-467-1989-en-plantas-de-energia-electrica-de-emergencia-768x382.jpg 768w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2024\/05\/NOM-J-467-1989-en-plantas-de-energia-electrica-de-emergencia-1536x764.jpg 1536w, https:\/\/www.itadviser.mx\/blog\/wp-content\/uploads\/2024\/05\/NOM-J-467-1989-en-plantas-de-energia-electrica-de-emergencia-2048x1019.jpg 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-eb64407 e-con-full e-flex e-con e-parent\" data-id=\"eb64407\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4f10957 elementor-widget elementor-widget-heading\" data-id=\"4f10957\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\"><p style=\"font-size: 16px;font-style: normal;font-weight: 400;text-align: justify\"><span><span style=\"font-weight: bold\">S\u00edguenos en nuestras redes sociales:<\/span><\/span><\/p><p style=\"font-size: 16px;font-style: normal;font-weight: 400;text-align: justify\"><\/p><a href=\"https:\/\/www.facebook.com\/p\/IT-Adviser-100063671183156\/\" style=\"font-size: 16px;font-weight: 400;text-align: justify;font-family: var( --e-global-typography-primary-font-family ), Sans-serif\" target=\"_blank\" rel=\"noopener\">Facebook<\/a><span style=\"font-size: 16px;font-weight: 400;text-align: justify;font-family: var( --e-global-typography-primary-font-family ), Sans-serif\">&nbsp;-&nbsp;<\/span><a href=\"https:\/\/www.instagram.com\/it_adviser_\/\" style=\"font-size: 16px;font-weight: 400;text-align: justify;font-family: var( --e-global-typography-primary-font-family ), Sans-serif\" target=\"_blank\" rel=\"noopener\">Instagram<\/a><span style=\"font-size: 16px;font-weight: 400;text-align: justify;font-family: var( --e-global-typography-primary-font-family ), Sans-serif\">&nbsp;-&nbsp;<\/span><a href=\"https:\/\/www.linkedin.com\/company\/itadvisersadecv\/\" style=\"font-size: 16px;font-weight: 400;text-align: justify;font-family: var( --e-global-typography-primary-font-family ), Sans-serif\" target=\"_blank\" rel=\"noopener\">LinkedIn<\/a><span style=\"font-size: 16px;font-weight: 400;text-align: justify;font-family: var( --e-global-typography-primary-font-family ), Sans-serif\">&nbsp;-&nbsp;<\/span><a href=\"https:\/\/www.itadviser.mx\/\" style=\"font-size: 16px;font-weight: 400;text-align: justify;font-family: var( --e-global-typography-primary-font-family ), Sans-serif\">Ecommerce<\/a><\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-92fa121 e-con-full e-flex e-con e-parent\" data-id=\"92fa121\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-911567c elementor-widget elementor-widget-shortcode\" data-id=\"911567c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">[doppler-form id='2']<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Por: Zabdiel Olvera | Asesor Comercial IT Adviser Seguridad y eficiencia con la NOM-J-467-1989 en Plantas Generadoras de Energ\u00eda El\u00e9ctrica En M\u00e9xico, el funcionamiento de las plantas generadoras de energ\u00eda el\u00e9ctrica de emergencia est\u00e1 regulado por un conjunto de normativas establecidas por el gobierno federal, las cuales son publicadas en el Diario Oficial de la [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":true,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","_monsterinsights_skip_tracking":false,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[51],"tags":[180,214,213,181],"class_list":["post-4048","post","type-post","status-publish","format-standard","hentry","category-electrico","tag-mantenimiento-a-plantas-de-emergencia","tag-plantas-de-emergencia-de-energia","tag-plantas-generadoras-de-energia","tag-plantas-de-emergencia"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false},"uagb_author_info":{"display_name":"Zabdiel Olvera","author_link":"https:\/\/www.itadviser.mx\/blog\/author\/zabdiel-olvera\/"},"uagb_comment_info":0,"uagb_excerpt":"Por: Zabdiel Olvera | Asesor Comercial IT Adviser Seguridad y eficiencia con la NOM-J-467-1989 en Plantas Generadoras de Energ\u00eda El\u00e9ctrica En M\u00e9xico, el funcionamiento de las plantas generadoras de energ\u00eda el\u00e9ctrica de emergencia est\u00e1 regulado por un conjunto de normativas establecidas por el gobierno federal, las cuales son publicadas en el Diario Oficial de la&hellip;","_links":{"self":[{"href":"https:\/\/www.itadviser.mx\/blog\/wp-json\/wp\/v2\/posts\/4048","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.itadviser.mx\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.itadviser.mx\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.itadviser.mx\/blog\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.itadviser.mx\/blog\/wp-json\/wp\/v2\/comments?post=4048"}],"version-history":[{"count":0,"href":"https:\/\/www.itadviser.mx\/blog\/wp-json\/wp\/v2\/posts\/4048\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.itadviser.mx\/blog\/wp-json\/wp\/v2\/media?parent=4048"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.itadviser.mx\/blog\/wp-json\/wp\/v2\/categories?post=4048"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.itadviser.mx\/blog\/wp-json\/wp\/v2\/tags?post=4048"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}